0
Vigor’s solvent purification systems are safe high-efficiency and convenient for customers to remove water and oxygen from flammable and noxious solvents.
Sold 0 items
0
Moisture<1 ppm, Oxygen<1 ppm Leakage Rate<0.001 vol%/h Clearroom:ISO-5, ISO-4
Sold 0 items
0
Vigor is ready to work with you to design any kind of system you may need, making new and challenging research projects possible.
Sold 0 items
0
Gloveboxes Minimize points of leakage and maintains your working atmosphere to
Sold 0 items
SDY Capacitive Level Sensor
Features ・ Ideal for indirect detection of liquids or powders in non-metallic containers. ・ Resistant to condensation, wetting and dirt on the inner wall of the container. ・ Adopting digital circuit for excellent noise resistance. ・ Two types are available for liquid and powder detection. ・ Compact and low cost.
Sold 0 items
MKCM Water / Oil Flow Switch
Features 《With Flow Switch》 By detecting the fluid flow, the switch is turned ON or OFF at the specified flow rate. The switch is fixed. The flow rate value cannot be changed later. 《 Visible Flow at a glance》 The flow of the fluid can be confirmed by the movement of the float in the transparent tube. 《With Protective Cover》 The metal protective cover reduces the possibility of damage due to impact from the outside.
Sold 0 items
MKCTV Water Signal / Oil Signal
Features 《Visible Flow Rate 》 Since a transparent taper tube is used, the approximate flow rate can be confirmed by looking at the position of the relationship between the ball and the indicated red line. 《With Flow Adjustment Valve》 By adjusting the miniature valve, the required flow rate can be set by aligning the ball with the red line. 《With Protective Cover》 The metal protective cover reduces the possibility of damage due to impact from the outside.
Sold 0 items
MKCT Water Signal / Oil Signal
Features 《Visible Flow Rate》 Since a transparent taper tube is used, the approximate flow rate can be confirmed by looking at the position of the relationship between the ball and the indicated red line. 《With Protective Cover》 The metal protective cover reduces the possibility of damage due to impact from the outside.
Sold 0 items
MKTV Water Signal / Oil Signal
Features 《Visible Flow Rate 》 Since a transparent taper tube is used, the approximate flow rate can be confirmed by looking at the position of the relationship between the ball and the indicated red line. 《With Flow Adjustment Valve》 By adjusting the miniature valve, the required flow rate can be set by aligning the ball with the red line.
Sold 0 items
MKT Water Signal / Oil Signal
Features 《Visible Flow Rate 》 Since a transparent taper tube is used, the approximate flow rate can be confirmed by looking at the position of the relationship between the ball and the indicated red line. 《Free Installation Posture》 Because using a spring inside, it can be installed in any posture, such as upward, downward, or sideways.
Sold 0 items
OF-Z Gear Type Flowsensor
Features »Ideal for measuring a variety of liquids. »Measures microflow rate with accuracy. »Excellent repeatability. »Viscous fluid is measurable.
Sold 0 items
ND Vane Wheel Flowsensor
Features »Ideal for measuring various liquids »Best-selling products with high quality at a low price ・Excellent repeatability. »Suitable for batch control »Lineup of 3 different wetted materials Measurement Principle The flow from the inlet is injected into the vane wheel and the vane wheel is rotated in proportion to the flow rate. A magnet is installed on the vane wheel, and the number of rotations is detected and output by the magnetic sensor. The structure of this flowsensor is simple and indestructible. This flowsensor operates smoothly from low flow rate range. In addition, the performance is excellently reproducible.
Sold 0 items
VN Compact Electromagnetic Flowsensor
Features ・Electromagnetic flowsensor without moving parts suitable for use in machines. ・With absence of moving parts, there is less failure due to its contaminants. ・Low pressure loss ・No straight pipe required, compact design, and easy to install. Measurement Principle By applying the Faraday’s law of induction, with a current flowing through the coil to generate a magnetic field in the flow path, an electromotive force is generated when a conductive liquid passes through the flow path. Electromagnetic force becomes signal which is proportional to flow velocity, and this voltage is measured to convert it to flow rate. The flow rate is calculated by multiplying this flow rate by the cross-sectional area of the flow path.
Sold 0 items
Clean Dry Air Generator Mini-CUBE SERIES(10NL/min)
MAIRS is the clean, dry air generator. It can supply the dry air that atmospheric pressure dew point can be less than -70 ℃.
Sold 0 items
Mini-CUBE SERIES(0.2NL/min-2NL/min)
Sold 0 items
MODEL 3000 SERIES
The Model 3000 Series maintains flow control characteristics with hysteresis of 15% or less (full-scale current). This ultra-compact proportional solenoid valve is perfect for automatic gas flow control of gas chromatographs and various other analyzers. With its high resolution, the Model 3000 is also suitable for precision pressure control.
Sold 0 items
RK140X
This multiple flow meter is made by combining several types of flow meter for control of various flows in a laboratory. It is designed based on the RK1400, a high-precision flow meter with high performance. It is recommended to install one unit to facilitate flow measurement in the laboratory.
Sold 0 items