Features
・Electromagnetic flowsensor without moving parts suitable for use in machines.
・With absence of moving parts, there is less failure due to its contaminants.
・Low pressure loss
・No straight pipe required, compact design, and easy to install.
Measurement Principle
By applying the Faraday’s law of induction, with a current
flowing through the coil to generate a magnetic field in the flow
path, an electromotive force is generated when a conductive
liquid passes through the flow path.
Electromagnetic force becomes signal which is proportional to
flow velocity, and this voltage is measured to convert it to flow
rate.
The flow rate is calculated by multiplying this flow rate by the
cross-sectional area of the flow path.